	<title>liquid cooled enclosures and chassis Archives - Boyd | Trusted Innovation</title>
	<atom:link href="https://www.boydcorp.com/tag/liquid-cooled-enclosures-and-chassis/feed" rel="self" type="application/rss+xml" />
	<link>https://www.boydcorp.com/tag/liquid-cooled-enclosures-and-chassis</link>
	<description>Boyd is a world-leading innovator of engineered material and thermal management technologies to seal, cool, and protect our customers most critical applications. We gain unparalleled technology insight solving complex challenges across the leading industries we serve. Our solutions maximize performance in 5G infrastructure and the world’s most advanced data centers; enhance reliability and extend range for electric and autonomous vehicles; advance the accuracy of cutting-edge personal healthcare and diagnostic systems, enable the latest generation of aircraft and defense technologies; and accelerate innovation in next-generation electronics and smartphones. Core to Boyd’s global, large-scale manufacturing is a deep commitment to protect the environment with sustainable, lean operations that reduce waste and minimize carbon footprint.</description>
	<lastBuildDate>Fri, 24 Jan 2025 17:15:42 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.boydcorp.com/wp-content/uploads/Home/Boyd-favicon.png</url>
	<title>liquid cooled enclosures and chassis Archives - Boyd | Trusted Innovation</title>
	<link>https://www.boydcorp.com/tag/liquid-cooled-enclosures-and-chassis</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Sizing a Heat Exchanger for Cold Plate Applications</title>
		<link>https://www.boydcorp.com/blog/sizing-heat-exchangers-for-liquid-cold-plates-and-cabinet-cooling-thermal-calculations.html</link>
		
		<dc:creator><![CDATA[Boyd Blog]]></dc:creator>
		<pubDate>Mon, 09 Sep 2019 12:53:00 +0000</pubDate>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[Liquid Cooling]]></category>
		<category><![CDATA[Thermal]]></category>
		<category><![CDATA[cold plate]]></category>
		<category><![CDATA[heat exchanger]]></category>
		<category><![CDATA[liquid cold plate]]></category>
		<category><![CDATA[liquid cooled enclosures and chassis]]></category>
		<category><![CDATA[thermal management]]></category>
		<guid isPermaLink="false">https://staging.boydcorp.com/sizing-heat-exchangers-for-liquid-cold-plates-and-cabinet-cooling-thermal-calculations/</guid>

					<description><![CDATA[<p>The post <a href="https://www.boydcorp.com/blog/sizing-heat-exchangers-for-liquid-cold-plates-and-cabinet-cooling-thermal-calculations.html">Sizing a Heat Exchanger for Cold Plate Applications</a> appeared first on <a href="https://www.boydcorp.com">Boyd | Trusted Innovation</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Calculating the Thermal Resistance of a Heat Exchanger</h2></div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_1">
				<div class="et_pb_column et_pb_column_1_2 et_pb_column_1  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_1  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Figure 1: shows a typical liquid cooling loop, consisting of a cold plate (CP), pump, and heat exchanger (HX) connected by hoses or tubing. Since the components are part of a system, it is important to select them together to ensure proper component sizing for your application. Manufacturers typically provide performance data for cold plates and heat exchangers individually, with cold plate performance in thermal resistance and heat exchanger performance in thermal capacity.</p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_2 et_pb_column_2  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_0">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="450" height="243" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Liquid-Cooling-Loop-Components.jpg" alt="Liquid Cooling Loop Components" title="" class="wp-image-13447" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_2">
				<div class="et_pb_column et_pb_column_2_3 et_pb_column_3  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_2  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>So how do you select the optimal heat exchanger and cold plate for the complete system? It is easier than you might think, since the equations needed to determine the right cold plate and heat exchanger combination reduce to a very simple format:</p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_3 et_pb_column_4  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_1">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="228" height="47" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/System-Thermal-Resistance-Liquid-Cooling-Formula.jpg" alt="System Thermal Resistance Liquid Cooling Formula" title="" class="wp-image-13439" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_3">
				<div class="et_pb_column et_pb_column_3_4 et_pb_column_5  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_3  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>To arrive at this equation, the first step is to calculate the cold plate thermal resistance, θCP, which is defined as the difference between the maximum required surface temperature, TS, MAX, and fluid exit temperature, TH, divided by a heat load, Q, evenly distributed over the entire cold plate surface:</p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_4 et_pb_column_6  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_2">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="120" height="47" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Liquid-Cold-Plate-Thermal-Resistance-Formula.jpg" alt="Liquid Cold Plate Thermal Resistance Formula" title="" class="wp-image-13444" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_4">
				<div class="et_pb_column et_pb_column_3_4 et_pb_column_7  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_4  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Similarly, heat exchanger thermal capacity, CHX, which is defined as the heat load, Q, divided by the temperature differential between two incoming fluids, TH -TAIR, is described by the following equation:</p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_4 et_pb_column_8  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_3">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="111" height="45" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Heat-Exchanger-Cooling-Capacity-Formula.jpg" alt="Heat Exchanger Cooling Capacity Formula" title="" class="wp-image-13442" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_5">
				<div class="et_pb_column et_pb_column_3_4 et_pb_column_9  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_5  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Thermal capacity is also equal to the inverse of thermal resistance:</p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_4 et_pb_column_10  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_4">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="77" height="45" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Thermal-Resistance-Thermal-Capacity-Formula-Heat-Exchanger.jpg" alt="Thermal Resistance Thermal Capacity Formula Heat Exchanger" title="" class="wp-image-13440" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_6">
				<div class="et_pb_column et_pb_column_2_3 et_pb_column_11  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_6  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Assuming no heat gains from the pump or heat losses through connecting hoses or tubing between the cold plate and heat exchanger (since these are usually minor), equations (2), (3) and (4) can be combined into one simple equation:</p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_3 et_pb_column_12  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_5">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="228" height="47" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/System-Thermal-Resistance-Liquid-Cooling-Formula.jpg" alt="System Thermal Resistance Liquid Cooling Formula" title="" class="wp-image-13439" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_7">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_13  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_7  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Hot process fluid temperature TH has dropped out of the formula because liquid temperature has been removed from the equation, we do not have to calculate flow rates and heat capacities of the liquid. We are just left with the desired surface temperature of the cold plate, as well as the temperature of ambient air cooling the heat exchanger, and the performance is fully characterized by the thermal resistances of the cold plate and heat exchanger. Therefore, we no longer have to analyze the individual components of the system. Instead we determine the thermal resistance of the entire system. Note that the effect of flow is not excluded from the results because it is already incorporated within thermal resistance values.</p>
<p>A customer wants to use a CP12 a 12&#8243; (30.48 cm) cold plate (plate side), to remove 1200 W of heat from a 12&#8243;x5&#8243; (30.48 cm x 12.70 cm) electronic device. The coolant is 1 gpm (3.785 LPM) of water and room temperature is 20°C. The customer wants the smallest heat exchanger that will remove 1200 W of heat generated by this device, while maintaining a maximum surface temperature of 80°C.</p></div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_8">
				<div class="et_pb_column et_pb_column_3_5 et_pb_column_14  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_8  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3>Step 1:</h3>
First we determine system thermal resistance, θSYSTEM:</div>
			</div>
			</div><div class="et_pb_column et_pb_column_2_5 et_pb_column_15  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_6">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="356" height="47" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Liquid-Cooling-System-Thermal-Resistance-Example-Calculation.jpg" alt="Liquid Cooling System Thermal Resistance Example Calculation" title="" class="wp-image-13438" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_9">
				<div class="et_pb_column et_pb_column_3_4 et_pb_column_16  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_9  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3>Step 2:</h3>
Any combination of cold plates and heat exchangers that provide a thermal resistance less than or equal to the total system requirement will work. In other words:</div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_4 et_pb_column_17  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_7">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="163" height="25" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Liquid-Cold-Plate-Heat-Exchanger-Thermal-Resistance-Example-Calculation.jpg" alt="Liquid Cold Plate Heat Exchanger Thermal Resistance Example Calculation" title="" class="wp-image-13446" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_10">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_18  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_10  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h3><strong>Step 3:</strong></h3>
<p>Table 1 shows the resistance and flow rates of the CP12 cold plate and two different heat exchanger/fan combinations:</p></div>
			</div><div class="et_pb_module et_pb_code et_pb_code_0">
				
				
				
				
				<div class="et_pb_code_inner">
<table id="tablepress-45" class="tablepress tablepress-id-45">
<thead>
<tr class="row-1">
	<th class="column-1">Flow Rate (gpm)</th><th class="column-2">θCP (CP12) (°C/W)</th><th class="column-3">θHX (6110 w/Kona fan) (°C/W)</th><th class="column-4">θHX (6210 w/Marin Fan) (°C/W)</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">0.5</td><td class="column-2">0.013</td><td class="column-3">0.049</td><td class="column-4">0.019</td>
</tr>
<tr class="row-3">
	<td class="column-1">1.0</td><td class="column-2">0.009</td><td class="column-3">0.046</td><td class="column-4">0.017</td>
</tr>
<tr class="row-4">
	<td class="column-1">1.5</td><td class="column-2">0.007</td><td class="column-3">0.044</td><td class="column-4">0.016</td>
</tr>
<tr class="row-5">
	<td class="column-1">1.5</td><td class="column-2">0.007</td><td class="column-3">0.044</td><td class="column-4">0.016</td>
</tr>
<tr class="row-6">
	<td class="column-1">2.0</td><td class="column-2">0.006</td><td class="column-3">0.042</td><td class="column-4">0.016</td>
</tr>
</tbody>
</table>
<!-- #tablepress-45 from cache --></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_11  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner">Table 1 shows that the CP12/6110 combination satisfies the 0.050 °C/W condition at 2 gpm (0.006 +0.042 = 0.048.</div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_11">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_19  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_12  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>By looking at the system as a whole, we start to see trade offs between the components, including how flow rate can impact heat exchanger selection. At low flow rates, cold plate thermal resistance increases. This requires a larger heat exchanger with more thermal capacity, and therefore lower thermal resistance. At higher flow rates, it is possible to use a smaller heat exchanger.</p>
<p>Liquid-to-air heat exchangers and cold plates are often combined in a fluid circuit, so it is important to understand how to select the components simultaneously to optimize your system&#8217;s performance. With accurate specifications and a simplified equation, selecting the components in your liquid cooling loop can be relatively straightforward. In addition, by selecting components from the same thermal vendor, you use components that are tested in a similar manner and are more likely to work well as a system.</p></div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_12">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_20  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_13  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Cabinet Cooling Thermal Calculations</h2>
<h3>How to Calculate the Required Thermal Resistance for a Cabinet or Enclosure</h3></div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_13">
				<div class="et_pb_column et_pb_column_3_4 et_pb_column_21  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_14  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Heat exchanger manufacturers usually present thermal performance data as a function of heat load and incoming air and water flow rates. This works well for applications where the heat exchanger is used to cool water with air, as you can simply plug in your heat load, air temperature, and liquid temperature to determine if it offers sufficient thermal performance.</p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_4 et_pb_column_22  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_8">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="189" height="44" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Mass-Flow-Rate-Calculation.jpg" alt="Mass Flow Rate Calculation" title="" class="wp-image-13445" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_14">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_23  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_15  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Cabinet cooling applications use the heat exchanger in the opposite configuration &#8211; cold water flows in the liquid circuit and warm air from the cabinet is cooled as it passes across heat exchanger fins. In cabinet cooling applications, you usually need to know the temperature of air as it enters the cabinet, and the maximum temperature that air in the cabinet will reach. Neither of these can be read directly from heat exchanger performance curves.</p>
<p>The usual way to calculate the temperature change of air is to use the mass flow rate calculation.</p>
<p>This can be time-consuming and prone to error.</p>
<p>To avoid these calculations, Boyd developed charts to quickly estimate temperature rise in common heat transfer media at various heat loads. Graphs are available for air, water, oil, and 30/70 ethylene glycol-water (EGW). To calculate temperature change, simply select the appropriate graph, look up your flow rate and heat load, and read off the temperature change. In our technical library under thermal reference you can view a pdf or our temperature change graphs.</p>
<p>When used in conjunction with product performance curves, these offer a quick and simple way of calculating the temperature of cold air entering the cabinet, and maximum air temperature in the cabinet.</p></div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_15">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_24  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_16  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Example Cabinet Cooling Calculation</h2></div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_16">
				<div class="et_pb_column et_pb_column_2_5 et_pb_column_25  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_9">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="350" height="439" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Heat-Exchanger-6310-Graph.jpg" alt="Heat Exchanger 6310 Graph" title="" class="wp-image-13448" /></span>
			</div>
			</div><div class="et_pb_column et_pb_column_3_5 et_pb_column_26  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_17  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>You are evaluating a 6310 heat exchanger with an Ostro fan for cooling an electronics cabinet. The water entering the heat exchanger is at 20°C and a flow rate of 1 gpm. The heat load, Q, is 2400W.</p>

<p>What is the temperature of cooled air entering the cabinet (i.e. the temperature of air leaving the heat exchanger) and what is maximum temperature in the cabinet (i.e. the temperature of warm air entering the heat exchanger)?</p>

<p>First check the performance curve of 6310 in the catalog. You will see that with a 1gpm water flow and the Ostro fan which supplies approximately 250 cfm, its performance is 80W/°C.</p></div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_17">
				<div class="et_pb_column et_pb_column_1_2 et_pb_column_27  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_18  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>Since we know that Q is 2400W and Q/ITD is 80°C/W, we can calculate Initial Temperature Difference (ITD).</p>
<p>ITD = 2400W ÷ 80°C/W = 30°C</p>
<p>We also know that incoming water temperature is 20°C. We can therefore calculate incoming air temperature:</p>
<p>The incoming air temperature = 20°C + 30°C = 50°C.</p>
<p>To determine outgoing temperature of the air, we use the &#8216;Air Flow&#8217; chart using parameters 250 CFM and 2400 W.</p></div>
			</div><div class="et_pb_module et_pb_text et_pb_text_19  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>We find the change in temperature is approximately 17°C. The outgoing air temperature is 50°C &#8211; 17°C = 33°C.</p>
<p>We know that this heat exchanger with the Ostro fan will cool air to 33°C, and the hottest temperature air in the cabinet will reach is 50°C.</p></div>
			</div>
			</div><div class="et_pb_column et_pb_column_1_2 et_pb_column_28  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_10">
				
				
				
				
				<span class="et_pb_image_wrap "><img decoding="async" width="432" height="546" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Air-Flow-Chart.jpg" alt="Air Flow Chart" title="" class="wp-image-13441" /></span>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_18">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_29  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_20  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>To determine the outgoing temperature of water we use the &#8216;Water Flow&#8217; chart.</p></div>
			</div>
			</div>
				
				
				
				
			</div><div class="et_pb_row et_pb_row_19">
				<div class="et_pb_column et_pb_column_1_2 et_pb_column_30  et_pb_css_mix_blend_mode_passthrough">
				
				
				
				
				<div class="et_pb_module et_pb_image et_pb_image_11">
				
				
				
				
				<a href="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Water-Flow-Chart.jpg" class="et_pb_lightbox_image" title="Water Flow Chart"><span class="et_pb_image_wrap "><img decoding="async" width="620" height="323" src="https://www.boydcorp.com/wp-content/uploads/Resources/Blog/Water-Flow-Chart.jpg" alt="Water Flow Chart" title="" class="wp-image-13384" /></span></a>
			</div>
			</div><div class="et_pb_column et_pb_column_1_2 et_pb_column_31  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_21  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><p>At 1 gpm and 2400 W, this shows that the change in temperature is approximately 9°C. Therefore, the outgoing water temperature is 20°C + 9°C = 29°C.</p>
<p>Graphs for air, water, oil, and EGW are available in downloadable PDF format. These are helpful for sizing heat exchangers and cold plates and are also useful in a variety of other temperature change calculations.</p></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div><p>The post <a href="https://www.boydcorp.com/blog/sizing-heat-exchangers-for-liquid-cold-plates-and-cabinet-cooling-thermal-calculations.html">Sizing a Heat Exchanger for Cold Plate Applications</a> appeared first on <a href="https://www.boydcorp.com">Boyd | Trusted Innovation</a>.</p>
]]></content:encoded>
					
		
		